gridseed-5-chip-asic-fanless-power-usage

If you are using the 5-chip Gridseed ASIC devices in Scrypt only mining mode you probably already know that they are using about 8W of power when overclocked. But what about optimizing the power usage even more by removing the noisy fan that might be needed for the 60W power usage in Dual mode or the 50 and something in BTC only mode, but you can go without it in Scrypt only mode. So we did just that, desoldered the fan from the ASIC and ran the device in fanless mode. And surprise, surprise the total power usage without the fan gets down to just about 5-6W overclocked to 850 MHz, but what about cooling without a fan?

gridseed-5-chip-asic-fanless-thermal-image

Running for more than 2 hours already the ASIC in fanless mode mining Scrypt has shown that it can do just fine with passive cooling. The maximum temperature was about 36.6 degrees Celsius at the hottest point with an ambient temperature of about 25 degrees Celsius. Don’t get the wrong impression from the thermal images, these temperatures for passive cooling are more than adequate and essentially the cooling radiator is considered cool, meaning that in Scrypt only mining mode you can do just fine with passive cooling at lower ambient temperatures. If you have multiple units together you might want to have a single big fan with slow rpm just to move a bit of air around them you you can be safe even when the summer heat hits.

A word of warning though, if you remove the fan from the Gridseed 5-chip ASIC devices and for some reason you start a miner for Scrypt that does not stop the BTC mining part or you start the dual mining mode you will have trouble with cooling the device and this can lead to a damage of the ASIC caused by overheating of the chips – most likely the first to blow up would be the voltage regulators. So be careful that you run only in Scrypt mode if going fanless and to use miners that do activate only the Scrypt mining mode and disable the SHA-256 one.


top